Range : EK9….L-EUF / BCS

• Two-stage progressive digital class 3 low Nox forced draught burner. • Fuel: light oil, viscosity 6 mm2/s at 20°C, low calorific value 11,86 kWh/kg. • Max...

Range : EK 03… GL-ZV

• Two-stage dual fuel forced draught burner. • Fuels : natural gas, net calorific value 8,83 … 10,53 kWh/m3. light oil, viscosity 6 mm2/s at 20°C, low...

Range : EK4 .… GL-RO

• Two-stage progressive mechanical dual fuel forced draught burner. • Fuels: natural gas, net calorific value 8,83 … 10,53 kWh/m3. light oil, viscosity 6...

Range : EK 6. … GL-R

• Two-stage progressive mechanical dual fuel forced draught burner. • Fuels: natural gas, net calorific value 8,83 … 10,53 kWh/m3. light oil, viscosity 6...

Range : EK 8. … GL-R

• Two-stage progressive mechanical dual fuel forced draught burner. • Fuels: natural gas, net calorific value 8,83 … 10,53 kWh/m3. light oil, viscosity 6...

Range : EK 6. … GL-RU

• Two stage progressive mechanical dual fuel forced draught burner. • Fuels: natural gas, net calorific value 8,83 … 10,53 kWh/m3, low NOx class 3. light...

Range : EK 8. … GL-RU

• Two-stage progressive mechanical dual fuel forced draught burner. • Fuels: natural gas, net calorific value 8,83 … 10,53 kWh/m3, low NOx class 3. light...

Range : EK 6. … GL-E / BCS

• Two-stage progressive digital dual fuel forced draught burner. • Fuels: natural gas, net calorific value 8,83 … 10,53 kWh/m3. light oil, viscosity 6 mm2/s at...

Range : EK 8. … GL-E / BCS

• Two-stage progressive digital dual fuel forced draught burner. • Fuels: natural gas, net calorific value 8,83 … 10,53 kWh/m3. light oil, viscosity 6 mm2/s at...

Range : EK 6. … GL-EU / BCS

• Two stage progressive digital dual fuel forced draught burner. • Fuels: natural gas, net calorific value 8,83 … 10,53 kWh/m3, low NOx class 3. light oil,...

Range : EK 8. … GL-EU / BCS

• Two-stage progressive digital dual fuel forced draught burner. • Fuels: natural gas, net calorific value 8,83 … 10,53 kWh/m3, low NOx class 3. light oil,...

Range : EK 6. … GL-EUF / BCS

• Two stage progressive digital low NOx dual fuel forced draught burner. • Free flame low NOx class 3 technology. • Fuels: natural gas, net calorific value...

Range : EK 8. … GL-EUF / BCS

• Two-stage progressive digital low NOx dual fuel forced draught burner. • Free flame low NOx class 3 technology. • Fuels: natural gas, net calorific value...

Range: Tectron® E10. … GL-EUF

• Two-stage progressive digital low NOx dual fuel forced draught burner. • Free flame low NOx class 3 technology. • Fuel: natural gas, net calorific value...

Range: EK 4. … S-ZA

• Two-stages forced draught burner. • Fuel: heavy oil, viscosity 20 … 350 mm2/s by 50°C, net calorific value 10,69 … 10,97 kWh/kg. • Max heat power: 1004...

Range: EK 5. … S-R

• Two stage progressive mechanical forced draught burner. • Fuel: heavy oil, viscosity 20 … 350 mm2/s by 50°C, net calorific value 10,69 … 10,97 kWh/kg....